DX51D+Z/DC51D+Z (CR) Galvanized Corrugated Plate
DX51D+Z and DC51D+Z (CR) galvanized corrugated plate, EN 10346 / GB/T 2518, hot-dip zinc coated, thickness 0.14–1.2 mm, zinc coating Z60–Z275, 9/11/12-wave profiles, for roofing, wall cladding, warehouse, fence and agricultural buildings. MTC available.
WhatsApp:+8619033681875
Email:judesteel@juqing.hk
Contact Us

Product Details

Short Description

We supply DX51D+Z / DC51D+Z (CR) galvanized corrugated plate, a hot-dip galvanized steel sheet formed into a corrugated profile for roofing, wall cladding and building envelope applications. The product is manufactured to EN 10346 / GB/T 2518, with DX51D+Z as the European standard grade and DC51D+Z (CR) as the cold-rolled substrate equivalent commonly used in Chinese and European trade practice.
DX51D+Z and DC51D+Z are both cold-forming quality hot-dip galvanized grades. DC51D+Z explicitly uses a cold-rolled (CR) substrate, while DX51D+Z does not specify the substrate rolling process and may be produced from cold-rolled or hot-rolled substrate. For corrugated roofing and wall sheets, both grades provide good formability, adequate strength and reliable corrosion protection.
Typical supply range: thickness 0.14–1.2 mm, width 600–1250 mm before forming, length 1000–12000 mm or custom, zinc coating Z60–Z275 (40–275 g/m²), with 9-wave, 11-wave, 12-wave, sine wave or trapezoidal profiles available.
Product nameDX51D+Z/DC51D+Z (CR) Galvanized Corrugated Plate
Applications1. Construction: Prefabricated houses, steel structure houses, mobile homes, modular houses, villas, bungalow design, mobile homes/wooden boxes, ready-made houses, kiosksBooth, steel construction......2. Container production3. Home appliances and furniture4. Production of vehicles and ships5. Other, such as mechanical structure parts, engine shell production, etc
Thickness0.12-4.0mm, according to your requirements
StandardsAstm, din.en.aisi. gb, jis enz, etc
Width600-1250mm, according to your requirements
Length6000-12000mm according to your requirements
SpecificationsSgcc, SGCH, G550, DX51D, DX52D, DX53D, ENZ.
Tolerance± 1%
Processing serviceswelding, punching, cutting, bending, unwinding
Delivery time7-15 days, depending on the situation and quantity
Type coating processFront: double coating double drying;Back: double coating double drying; Single coating double sun;

What Is DX51D+Z / DC51D+Z (CR) Galvanized Corrugated Plate

Galvanized corrugated plate is produced from hot-dip galvanized steel coil and then roll-formed into a regular wave pattern. The zinc coating protects the steel from corrosion, while the corrugated profile increases stiffness, improves rainwater drainage and allows longer spans with fewer supports.
DX51D+Z is defined under EN 10346 as a continuously hot-dip coated steel flat product for cold forming. The grade is widely used in construction, HVAC, appliances and general metal fabrication.
DC51D+Z is the same cold-forming grade series but explicitly indicates a cold-rolled (CR) substrate. In trade practice, DC51D+Z (CR) is often specified when buyers require a cold-rolled base for better surface quality and dimensional consistency.
The corrugated forming process converts flat galvanized coil into a structural sheet profile. Common profiles include sine wave, trapezoidal, 9-wave, 11-wave and 12-wave, depending on coil width, market preference and project design.

Grade Explanation: DX51D+Z vs DC51D+Z

ItemDX51D+ZDC51D+Z (CR)
ItemDX51D+ZDC51D+Z (CR)
StandardEN 10346 / GB/T 2518EN 10346 / Chinese trade practice
SubstrateCold-rolled or hot-rolled (not specified)Cold-rolled (CR) substrate required
Grade Series51 = commercial quality / general cold forming51 = commercial quality / general cold forming
Coating+Z = hot-dip pure zinc coating+Z = hot-dip pure zinc coating
Typical UseRoofing, wall sheet, HVAC, general fabricationRoofing, wall sheet, appliances, precision forming
Key DifferenceSubstrate process not specifiedExplicitly cold-rolled substrate
Naming breakdown (EN 10346 / GB/T 2518):
  • D = flat steel for cold forming
  • X = substrate rolling process not specified (DX51D+Z)
  • C = cold-rolled substrate (DC51D+Z)
  • 51 = commercial quality / general cold-forming grade series
  • D = hot-dip coating process
  • Z = pure zinc coating

Chemical Composition (Typical)

ElementDX51D+Z (%)DC51D+Z (%)
ElementDX51D+Z (%)DC51D+Z (%)
C≤0.12≤0.12
Mn≤0.60≤0.60
P≤0.025≤0.030
S≤0.025≤0.035
Als≥0.020≥0.020
Composition ranges are typical reference values for EN 10346 DX51D / DC51D grades and shall be confirmed by heat analysis and MTC.

Mechanical Properties

PropertyDX51D+ZDC51D+Z
PropertyDX51D+ZDC51D+Z
Yield Strength (ReH)≥140 MPa≥230 MPa
Tensile Strength (Rm)270–500 MPa270–500 MPa
Elongation (A80mm)≥22%≥22%
Values are typical for DX51D / DC51D grade series under EN 10346 and may vary with thickness, coating mass and production route.

Zinc Coating Selection

The zinc coating mass determines corrosion resistance and service life. Higher zinc coating is recommended for outdoor, coastal or high-humidity environments.
CoatingApprox. Mass (g/m²)Recommended Use
CoatingApprox. Mass (g/m²)Recommended Use
Z6060Indoor, temporary structures, low-corrosion environments
Z8080Indoor humid environments, light outdoor use
Z100100General outdoor roofing, agricultural buildings
Z120120Standard industrial roofing and wall cladding
Z140140Outdoor buildings with moderate corrosion risk
Z180180Standard outdoor use, salt spray resistance approx. 1200h+
Z275275Coastal, high-humidity, heavy corrosion environments
Zinc coating mass tolerance is typically ±15% per EN 10346. For example, Z275 corresponds to approximately 248–302 g/m².

Common Corrugated Profiles

The profile affects stiffness, drainage, appearance and effective coverage width. Common profiles for DX51D+Z / DC51D+Z galvanized corrugated plate include:
ProfileTypical Coil WidthEffective WidthCommon Use
ProfileTypical Coil WidthEffective WidthCommon Use
9-wave762 mm650–680 mmAgricultural sheds, simple roofing
11-wave914 mm780–815 mmResidential roofing, wall cladding
12-wave1000 mm875–930 mmStandard roofing, warehouses
Sine wave600–1250 mmVariesGeneral roofing, fencing
Trapezoidal600–1250 mmVariesIndustrial roofing, structural cladding
Tile profile914–1000 mmVariesVillas, residential buildings
Profile dimensions vary by mill and customer market. Buyers should confirm both raw coil width and effective width after forming.

Applications

1. Roofing sheets
DX51D+Z / DC51D+Z galvanized corrugated plate is widely used for factory roofs, warehouse roofs, agricultural sheds, residential garages and temporary housing.
2. Wall cladding
The corrugated profile provides stiffness and weather resistance, making it suitable for industrial wall panels, fence panels and building enclosures.
3. Agricultural buildings
Commonly used for poultry houses, cattle sheds, grain storage and farm workshops where cost-effective, durable sheeting is required.
4. Industrial and commercial buildings
Suitable for steel structure buildings, logistics warehouses, workshops, site offices and commercial enclosures.
5. Fencing and enclosures
Galvanized corrugated plate is used for construction site fencing, boundary walls, sound barriers and temporary enclosures.
6. HVAC and general fabrication
The base grade is also used for ventilation ducts, appliance casings, electrical cabinets and metal furniture, though corrugated form is mainly for construction applications.

Manufacturing Process

1.Coil selection

High-quality cold-rolled or hot-rolled steel coil is selected as substrate. For DC51D+Z (CR), cold-rolled substrate is used.

2.Cleaning and pretreatment

The coil is degreased, pickled and fluxed to remove oil, rust and mill scale, ensuring good zinc adhesion.

3.Hot-dip galvanizing

The steel strip passes through a molten zinc bath, forming a metallurgical zinc-iron coating. Coating mass is controlled to Z60–Z275 as required.

4.Skin pass and surface treatment
The galvanized sheet may be skin-pass rolled, chromated or non-chromated passivated, and supplied with regular spangle, small spangle or zero spangle.

5.Cut-to-length or coil supply

Galvanized coil is slit or cut to required width and length before forming.

6.Corrugated roll-forming

The flat galvanized sheet is passed through a series of roll-forming machines to create a continuous wave profile. The roll-forming process increases the stiffness of the sheet, improves rainwater drainage, and allows the sheet to span longer distances between structural supports.

7.Cutting to length
The formed corrugated sheets are cut to the required length by flying shear or post-forming saw cutting. Custom lengths help reduce on-site waste and speed up installation.
8.Surface protection
Depending on the market requirement, the sheets may be supplied with chromated or non-chromated passivation, anti-fingerprint treatment, or oiled surface to prevent white rust during storage and shipping.

Quality Control Points

To ensure consistent export quality, the following quality control points are strictly checked during production and before loading:

* Substrate verification: Confirm cold-rolled substrate for DC51D+Z (CR); confirm grade traceability for DX51D+Z.

* Zinc coating uniformity: Coating mass must meet the ordered Z-class (e.g., Z100, Z180, Z275) with tolerance within ±15% per EN 10346.

* Surface defect control: No visible rust, oil stains, dents, scratches, or edge damage.

* Flatness and camber: Sheets must be flat without excessive wave, bow, or twist to ensure smooth installation.

* Edge condition: Cut edges must be free of burrs, cracks, and sharp fins.

* Profile accuracy: Wave height, pitch, and effective width must match the agreed profile drawing.

* Packaging inspection: Bundles must be securely strapped, waterproofed, and labeled correctly.

Call to Action

Looking for reliable DX51D+Z / DC51D+Z (CR) galvanized corrugated plate for your roofing or wall cladding project?
Send us your grade, thickness, width, length, zinc coating requirement, corrugated profile, quantity, and destination port, and we will provide a detailed export quotation with MTC support.Click here to get a quote now.

TEL:+86 19063793739 / +86 029 86382955

WhatsApp:+86 19033681875

Email:judesteel@juqing.hk

Samples, MTC review, and third-party inspection are available.

Product Display

1787563800950445228035698688.webp@!w400


Product Application

1787564344950447507224662016.jpg@!w400


Packaging and shipping

DX51D+Z/DC51D+Z (CR) Galvanized Corrugated Plate


Factory Display

  • a635e6aa8af749b3b20947091f812fdd
  • 011177a38e499b8b50e0993f29e85558
  • 60a465fb6d089d1e3a0c90958431d3c3
  • 未标题-2
  • 摄图网_600975422_钢铁仓库(非企业商用)-(1)
  • vecteezy_modern-industrial-steel-manufacturing-facility-with-advanced_49740735
  • 0b42940c953e9e845fc286c7d6151ed6
  • 25a2288e2c3f5a265b436ee9de2c6480
  • bf4177c383f74c00f80e0bca1aae52a7
  • 工厂车间 (4)
  • Stainless-Steel-Pipe-Manufacturers
  • 4ba06389467ca90624596b987abe434be8635cba188343-TdLEpR 拷贝
  • 645f88ceb28016b71deb44d0eca6ae91346ff4f633046-YV9trp
  • 76e854f676be41a74b86935d2042824d

FAQ

A:

Both are commercial-quality hot-dip galvanized grades under EN 10346. DC51D+Z explicitly requires a cold-rolled (CR) substrate, while DX51D+Z does not specify the substrate rolling process and may be produced from cold-rolled or hot-rolled substrate. For most corrugated roofing applications, both grades perform similarly.

A:

For general outdoor roofing, Z100 to Z180 is commonly used. For coastal or high-humidity environments, Z275 is recommended for longer service life. For indoor or temporary structures, Z60 to Z80 may be sufficient.

A:

Yes. If you need color-coated corrugated sheet, we can supply PPGI / color coated corrugated sheet based on DX51D+Z or DC51D+Z substrate with polyester, SMP, HDP, or PVDF paint systems.

A:

MOQ depends on size and stock availability. For standard sizes, MOQ is usually around 5–10 tons per size. Trial orders can be discussed for mixed sizes.

A:

Yes. A mill test certificate is provided with every shipment, showing heat number, grade, chemical composition, mechanical properties, coating mass, and test results.

A:

Yes. We can cut corrugated sheets to custom lengths according to your project requirements. Custom lengths help reduce on-site cutting waste and speed up installation.

A:

Common profiles include 9-wave, 11-wave, 12-wave, sine wave, trapezoidal, and tile profile. The available profile depends on coil width and customer market preference. Please confirm both raw coil width and effective width after forming.

Contact Us

Submit

recommendation