SGC340/400/440/490/570 Galvanized Steel Wire
SGC340, SGC400, SGC440, SGC490 and SGC570 galvanized steel wire to JIS G 3302, hot-dip zinc coated, diameters 0.8–6.0 mm, soft to high tensile, for fencing, mesh, binding, strapping, cable armouring and light structural use. MTC available.
WhatsApp:+8619033681875
Email:judesteel@juqing.hk
Contact Us

Product Details

Short Description

We supply SGC340, SGC400, SGC440, SGC490 and SGC570 galvanized steel wire, produced from JIS G 3302 hot-dip galvanized structural steel grades and drawn into round wire with a continuous zinc coating. These grades are designed for applications where higher tensile strength, better load-bearing capacity and reliable corrosion resistance are required compared with general-purpose commercial galvanized wire.
SGC340, SGC400, SGC440, SGC490 and SGC570 are originally defined in JIS G 3302 for hot-dip zinc-coated steel sheet and strip. When converted into wire, the same grade logic is used to indicate increasing structural strength. The “SGC” designation refers to hot-dip galvanized steel, and the number indicates the minimum tensile strength level. Typical tensile strength requirements are approximately ≥340 MPa for SGC340, ≥400 MPa for SGC400, ≥440 MPa for SGC440, ≥490 MPa for SGC490 and ≥570 MPa for SGC570, subject to diameter, processing route and mill certificate.

This product is suitable for fencing, welded mesh, gabion wire, binding wire, strapping wire, cable armouring, stay wire, agricultural wire, light structural components and general hardware where galvanized protection and controlled strength are required.

What SGC340/400/440/490/570 Means

GradeStrength levelTypical wire use
GradeStrength levelTypical wire use
SGC340General structural gradeLight fencing, mesh, binding, simple formed wire
SGC400Medium structural gradeHeavier mesh, fencing, strapping, light supports
SGC440Medium-high structural gradeGabion, welded mesh, cable armouring, hardware
SGC490High structural gradeHigh-tension fencing, strapping, reinforced wire
SGC570Highest strength in this rangeStay wire, high-load fencing, structural wire
The SGC series is commonly referenced together with SGCC, SGCD, SGCH and SGHC in JIS G 3302. SGCC and SGCD grades are mainly commercial and drawing grades, while SGC340–SGC570 are positioned as structural grades with higher tensile requirements.

Product Specifications

ItemDetails
ItemDetails
Product NameSGC340/400/440/490/570 Galvanized Steel Wire
Standard ReferenceJIS G 3302 grade family; wire processed per customer specification
Grades AvailableSGC340, SGC400, SGC440, SGC490, SGC570
Wire Diameter0.8–6.0 mm common; other sizes on request
TemperSoft, half-hard, hard, high tensile as required
Zinc CoatingHot-dip galvanized; coating mass confirmed by diameter and application
Typical Coating Rangeapprox. 40–300 g/m² depending on diameter and class
SurfaceBright, uniform zinc coating; no rust, no peeling, no bare spots
Coil Weight50–1000 kg per coil, or per customer requirement
PackingPlastic-lined coils, wooden reels, hessian cloth or as agreed
CertificateMTC; third-party inspection available on request
Trade TermsFOB, CFR, CIF, EXW; T/T, L/C
Lead TimeUsually 15–30 days depending on grade, diameter, coating and quantity

Final tensile strength, elongation, coating mass and dimensional tolerance shall be confirmed before production. For wire products, the governing values are those agreed in the order specification and shown on the mill test certificate.

Mechanical Properties — Grade Overview

The following values are indicative grade references based on the JIS G 3302 sheet/strip designation and typical wire conversion practice.
GradeMin. tensile strengthTypical wire applications
GradeMin. tensile strengthTypical wire applications
SGC340≥ 340 MPaLight mesh, binding, general fencing, low-load formed wire
SGC400≥ 400 MPaMedium-duty fencing, strapping, welded mesh, hardware
SGC440≥ 440 MPaGabion wire, cable armouring, heavier mesh, structural wire
SGC490≥ 490 MPaHigh-tension fencing, stay wire, reinforced binding
SGC570≥ 570 MPaHigh-load fencing, support wire, high-strength strapping

Elongation decreases as tensile strength increases. SGC340 wire retains better bending and wrapping ability, while SGC570 wire provides higher load capacity but less forming flexibility. For applications involving tight coiling, knotting or repeated bending, SGC340 or SGC400 is usually more suitable. For long-span fencing, stay wires or high-tension mesh, SGC440, SGC490 or SGC570 may be preferred.

Zinc Coating and Corrosion Resistance

Hot-dip galvanizing provides sacrificial zinc protection to the steel substrate. The zinc layer protects the wire surface and also offers some protection at cut edges and minor scratches.
Coating mass should be selected according to service environment:
  • Light coating: indoor storage, dry environments, short-term protection
  • Medium coating: general outdoor fencing, mesh, binding, agricultural use
  • Heavy coating: coastal areas, high humidity, long-life outdoor structures
  • Extra-heavy coating: cable armouring, severe corrosion environments, long-term exposure

For wire, coating is often expressed as g/m² of wire surface. The required coating mass depends on diameter, drawing process and whether the wire is galvanized before drawing, galvanized after drawing, or processed by a galvanize–draw–regalvanize route.

Common Applications

1. Fencing and boundary wire
SGC340 and SGC400 are suitable for general field fencing, garden fencing and agricultural enclosures. SGC440 and SGC490 are better where higher tension or longer spans are required.
2. Welded wire mesh and gabion wire
Mesh panels, gabion baskets and reinforcement mesh benefit from controlled tensile strength and reliable zinc adhesion. SGC340–SGC440 are commonly used depending on mesh size and load requirement.
3. Binding and strapping wire
Construction binding, coil strapping, bale tying and packaging wire can use SGC340 or SGC400 with suitable temper. Higher grades are used where breakage risk must be reduced.
4. Cable armouring and communication wire
Galvanized steel wire is widely used for cable armouring and mechanical protection. SGC440 and SGC490 grades are often specified where tensile strength and corrosion resistance are both important.
5. Stay wire and support wire
Pole stays, guy wires, temporary supports and light structural ties may require SGC490 or SGC570, especially when the wire must carry sustained tension.
6. Agricultural and livestock wire

Farm fencing, animal enclosures, trellis wire and greenhouse support wire typically need moderate strength and good outdoor durability. SGC340 and SGC400 with medium or heavy zinc coating are practical choices.


How to Choose the Right SGC Grade

Choose SGC340 when:
The wire is used for light fencing, binding, simple mesh or general hardware where bending and wrapping are required.
Choose SGC400 when:
Higher strength is needed but the wire still requires reasonable flexibility for mesh welding, tying or light forming.
Choose SGC440 when:
The application involves gabion mesh, cable armouring, heavier welded mesh or moderate structural load.
Choose SGC490 when:
The wire must resist higher tension, such as stay wires, high-tension fencing or heavy strapping.
Choose SGC570 when:
Maximum tensile capacity is required and forming is limited, such as high-load support wires or specialized structural applications.

Processing and Quality Control

Drawing and temper control
Wire diameter, tensile strength and elongation are controlled through drawing reduction and heat treatment. Soft temper improves bending; hard temper increases strength.
Galvanizing route
Depending on diameter and performance requirements, wire can be processed as pre-galvanized, post-galvanized or redrawn after galvanizing. The route affects coating thickness, surface finish and mechanical properties.
Coating adhesion
The zinc layer should remain adherent during wrapping, bending and normal handling. Peeling, flaking or bare spots should be avoided.
Dimensional tolerance
Diameter tolerance, ovality and straightness should be agreed before production, especially for automated mesh welding or strapping lines.
Inspection items
Typical inspection includes tensile strength, elongation, wrapping test, torsion test, coating mass, coating uniformity, surface quality and dimensional check. MTC is provided with each batch.

Packaging & Shipping

  • Coils wrapped with plastic film and moisture-resistant paper
  • Wooden reels for larger diameters or export orders
  • Steel straps to secure coils and prevent loosening
  • Protective inner layer to reduce surface abrasion
  • Grade, diameter, coil weight, batch number and heat number marked on each coil
  • Documents: MTC, packing list, commercial invoice, bill of lading, inspection report where arranged
  • Stored in dry, ventilated conditions to prevent white rust and moisture damage

Call to Action

Send us the grade, diameter, temper, zinc coating mass, coil weight, application and destination port. We will confirm the suitable tensile level, coating specification and delivery schedule, and provide an export quotation within 24 hours.Click here to get a quote now.

TEL:+86 19063793739 / +86 029 86382955

WhatsApp:+86 19033681875

Email:judesteel@juqing.hk

Samples, MTC review and third-party inspection are available.


Product Display

SGC340/400/440/490/570 Galvanized Steel Wire

Product Application

1787990622952235447362088960.png@!w400


Packaging and shipping

SGC340/400/440/490/570 Galvanized Steel Wire

Factory Display

  • a635e6aa8af749b3b20947091f812fdd
  • 011177a38e499b8b50e0993f29e85558
  • 60a465fb6d089d1e3a0c90958431d3c3
  • 未标题-2
  • 摄图网_600975422_钢铁仓库(非企业商用)-(1)
  • vecteezy_modern-industrial-steel-manufacturing-facility-with-advanced_49740735
  • 0b42940c953e9e845fc286c7d6151ed6
  • 25a2288e2c3f5a265b436ee9de2c6480
  • bf4177c383f74c00f80e0bca1aae52a7
  • 工厂车间 (4)
  • Stainless-Steel-Pipe-Manufacturers
  • 4ba06389467ca90624596b987abe434be8635cba188343-TdLEpR 拷贝
  • 645f88ceb28016b71deb44d0eca6ae91346ff4f633046-YV9trp
  • 76e854f676be41a74b86935d2042824d

FAQ

A:

It is hot-dip galvanized steel wire produced from JIS G 3302 structural galvanized grades. The numbers indicate increasing tensile strength levels, from general structural SGC340 to high-strength SGC570.

A:

No. SGCC and DX51D are general commercial forming grades. SGC340–SGC570 are structural grades with higher tensile strength requirements. They are more comparable to EN S280GD+Z, S350GD+Z or S550GD+Z type grades, though exact equivalence must be confirmed by mechanical properties.

A:

For general agricultural or garden fencing, SGC340 or SGC400 is usually sufficient. For high-tension fencing, long-span wire or heavy-duty boundary fencing, SGC440 or SGC490 is more suitable.

A:

SGC340 and SGC400 work well for light to medium mesh. SGC440 is often preferred for gabion baskets and heavier welded mesh where higher wire strength is required.

A:

Indoor or short-term use may accept lighter coating. General outdoor fencing and mesh usually benefit from medium coating. Coastal, humid or long-life applications should specify heavier hot-dip coating.

A:

SGC570 provides high tensile strength but lower elongation. It is not ideal for very tight bending, knotting or repeated forming. For such processes, SGC340 or SGC400 is safer.

A:

Yes. MTC is provided for each batch, showing grade, diameter, tensile strength, elongation, coating mass and heat/batch information. Third-party inspection can be arranged on request.

A:

Yes. On request, we can supply comparable structural galvanized wire based on EN 10346, ASTM A653 or project-specific specifications. Cross-grade confirmation should be based on tensile strength, coating and application requirements.

Contact Us

Submit

recommendation